dc.descriptionMaster's thesis in Petroleum engineeringen_US
dc.description.abstractThis project presents a methodology to superimpose the API uniaxial and triaxial limits on the design limits plot. Complications due to a recent change of axis are resolved, producing practical design limits plots that avoid the horizontal shift of the API vertical limits, currently done by the industry. The commonly used slanted ellipse is compared against an adaptation of the circle of plasticity in the form of a horizontal ellipse, showing the convenience of this last one with examples. After a new collapse formulation was introduced in API TR 5C3 in 2015, the hor- izontal axis on the standard industry well tubular design limits plot changed. The study evaluates this rede nition of the horizontal axis. One consequence of this modi cation is a di culty plotting the API tension and compression limits. The API horizontal limits (uniaxial burst and collapse) are found to be independent of load case, while the API vertical design limits (uniaxial tension and compression) are dependent on inside and outside tubular pressures. The approaches used by commercial software and industry publications to solve this challenge are analyzed. A new design methodology is developed to link API limits to the triaxial theory. The main objective of the study is to establish a mathematical relationship between API tubular design limits and the Von Mises triaxial theory. A methodology that allows plotting the API uniaxial force limits on the design limit plot is developed. The study also shows that the results obtained from the industry standard slanted ellipse are identical to those obtained from the horizontal ellipse/circle and therefore the new plotting methodology can be applied to the last one as well. A di erence is that the slanted ellipse is based on zero axial stress datum while the horizontal ellipse/circle uses neutral axial stress datum. The horizontal ellipse/circle is well suited for calculations involving buckling, is compatible with the information used in eld operations, and its formulations are less complicated than in the tilted ellipse, therefore attention is called to it.en_US
dc.language.isoengen_US
dc.publisherUniversity of Stavanger, Norwayen_US
dc.relation.ispartofseriesMasteroppgave/UIS-TN-IEP/2020;
dc.subjectpetroleumsteknologen_US
dc.subjectboreteknologien_US
dc.titleCompatibility between API equations and design limits plots for ellipse and circle of plasticityen_US
dc.typeMaster thesisen_US
dc.subject.nsiVDP::Teknologi: 500::Berg‑ og petroleumsfag: 510::Petroleumsteknologi: 512en_US