Vis enkel innførsel

dc.contributor.authorRettedal, Siren
dc.contributor.authorEilevstjønn, Joar
dc.contributor.authorKibsgaard, Amalie
dc.contributor.authorKvaløy, Jan Terje
dc.contributor.authorErsdal, Hege Langli
dc.date.accessioned2022-03-03T14:16:03Z
dc.date.available2022-03-03T14:16:03Z
dc.date.created2022-01-06T18:53:51Z
dc.date.issued2021-11
dc.identifier.citationRettedal, S., Eilevstjønn, J., Kibsgaard, A., Kvaløy, J. T., & Ersdal, H. (2021). Comparison of Heart Rate Feedback from Dry-Electrode ECG, 3-Lead ECG, and Pulse Oximetry during Newborn Resuscitation. Children, 8(12), 1092.en_US
dc.identifier.issn2227-9067
dc.identifier.urihttps://hdl.handle.net/11250/2982882
dc.description.abstractBackground: Assessment of heart rate (HR) is essential during newborn resuscitation, and comparison of dry-electrode ECG technology to standard monitoring by 3-lead ECG and Pulse Oximetry (PO) is lacking. Methods: NeoBeat, ECG, and PO were applied to newborns resuscitated at birth. Resuscitations were video recorded, and HR was registered every second. Results: Device placement time from birth was median (quartiles) 6 (4, 18) seconds for NeoBeat versus 138 (97, 181) seconds for ECG and 152 (103, 216) seconds for PO. Time to first HR presentation from birth was 22 (13, 45) seconds for NeoBeat versus 171 (129, 239) seconds for ECG and 270 (185, 357) seconds for PO. Proportion of time with HR feedback from NeoBeat during resuscitation from birth was 85 (69, 93)%, from arrival at the resuscitation table 98 (85, 100)%, and during positive pressure ventilation 100 (95, 100)%. For ECG, these proportions were, 25 (0, 43)%, 28 (0, 56)%, and 33 (0, 66)% and for PO, 0 (0, 16)%, 0 (0, 16)%, and 0 (0, 18)%. All p < 0.0001. Conclusions: NeoBeat was faster to place, presented HR more rapidly, and provided feedback on HR for a larger proportion of time during ongoing resuscitation compared to 3-lead ECG and PO.en_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjectpediatrien_US
dc.subjectECGen_US
dc.subjectnyfødtgjenopplivingen_US
dc.subjectnewborn resuscitationen_US
dc.titleComparison of heart rate feedback from dry-electrode ecg, 3-lead ecg, and pulse oximetry during newborn resuscitationen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© 2021 by the authorsen_US
dc.subject.nsiVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750::Pediatri: 760en_US
dc.source.pagenumber1-11en_US
dc.source.volume8en_US
dc.source.journalChildrenen_US
dc.source.issue12en_US
dc.identifier.doi10.3390/children8121092
dc.identifier.cristin1976201
dc.source.articlenumber1092en_US
cristin.ispublishedtrue
cristin.fulltextpostprint
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel

Navngivelse 4.0 Internasjonal
Med mindre annet er angitt, så er denne innførselen lisensiert som Navngivelse 4.0 Internasjonal