Show simple item record

dc.contributor.authorRettedal, Siren
dc.contributor.authorKibsgaard-Petersen, Amalie
dc.contributor.authorEilevstjønn, Joar
dc.contributor.authorKvaløy, Jan Terje
dc.contributor.authorBjorland, Peder Aleksander
dc.contributor.authorLillevik, Hanne Markhus
dc.contributor.authorHaynes, Joanna Clare
dc.contributor.authorTysland, Thomas Bailey
dc.contributor.authorStørdal, Ketil
dc.contributor.authorHolte, Kari
dc.contributor.authorDavis, Peter G
dc.contributor.authorErsdal, Hege Langli
dc.date.accessioned2023-03-23T07:57:02Z
dc.date.available2023-03-23T07:57:02Z
dc.date.created2022-10-15T14:02:55Z
dc.date.issued2022
dc.identifier.citationRettedal, S., Kibsgaard, A., Eilevstjønn, J., Kvaløy, J. T., Bjorland, P. A., Pike, H. M., ... & Ersdal, H. L. (2022). Impact of immediate and continuous heart rate feedback by dry electrode ECG on time to initiation of ventilation after birth: protocol for a randomised controlled trial. BMJ Open, 12(9), e061839.en_US
dc.identifier.issn2044-6055
dc.identifier.urihttps://hdl.handle.net/11250/3060005
dc.description.abstractIntroduction 3%–8% of newborns need positive pressure ventilation (PPV) after birth. Heart rate (HR) is considered the most sensitive indicator of the newborns’ condition and response to resuscitative interventions. According to guidelines, HR should be assessed and PPV initiated within 60 s after birth in non-breathing newborns. Dry electrode ECG can provide accurate feedback on HR immediately after birth and continuously during resuscitation. The impact of early and continuous HR feedback is unknown. Method and analysis This single-centre randomised controlled trial seeks to determine if HR feedback by dry electrode ECG immediately after birth and continuously during newborn resuscitation results in more timely initiation of PPV, improved ventilation and short-term outcomes compared with standard HR assessment. In all newborns≥34 gestational weeks, the dry electrode ECG sensor is placed on the upper abdomen immediately after birth as an additional modality of HR assessment. The device records and stores HR signals. In intervention subjects, the HR display is visible to guide decision-making and further management, in control subjects the display is masked. Standard HR assessment is by stethoscope, gel-electrode ECG and/or pulse oximetry (PO). Time of birth is registered in the Liveborn app. Time of initiation and duration of PPV is calculated from video recordings. Ventilation parameters are retrieved from the ventilation monitor, oxygen saturation and HR from the PO and gel-electrode ECG monitors. The primary endpoint is proportion of resuscitated newborns who receive PPV within 60 s after birth. To detect a 50% increase with power of 90% using an overall significance level of 0.05 and 1 interim analysis, 169 newborns are needed in each group. Ethics and dissemination Approval by the Norwegian National Research Ethics Committee West (2018/338). Parental consent is sought at routine screening early in pregnancy. The results will be published in peer-reviewed journal and presented at conferences.en_US
dc.language.isoengen_US
dc.publisherBMJ Publishing Groupen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.titleImpact of immediate and continuous heart rate feedback by dry electrode ECG on time to initiation of ventilation after birth: protocol for a randomised controlled trialen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holderThe authorsen_US
dc.subject.nsiVDP::Medisinske Fag: 700en_US
dc.source.volume12en_US
dc.source.journalBMJ Openen_US
dc.source.issue9en_US
dc.identifier.doi10.1136/bmjopen-2022-061839
dc.identifier.cristin2061641
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal