Vis enkel innførsel

dc.contributor.authorMeinich-Bache, Øyvind
dc.contributor.authorEngan, Kjersti
dc.contributor.authorBirkenes, Tonje Søraas
dc.contributor.authorMyklebust, Helge
dc.date.accessioned2018-11-09T08:43:28Z
dc.date.available2018-11-09T08:43:28Z
dc.date.created2018-11-07T13:21:34Z
dc.date.issued2018-10
dc.identifier.citationMeinich-Bache, Ø. et al. (2018) Real-Time Chest Compression Quality Measurements by Smartphone Camera. Journal of Healthcare Engineering. Article ID 6241856,nb_NO
dc.identifier.issn2040-2295
dc.identifier.urihttp://hdl.handle.net/11250/2571727
dc.description.abstractOut-of-hospital cardiac arrest (OHCA) is recognized as a global mortality challenge, and digital strategies could contribute to increase the chance of survival. In this paper, we investigate if cardiopulmonary resuscitation (CPR) quality measurement using smartphone video analysis in real-time is feasible for a range of conditions. With the use of a web-connected smartphone application which utilizes the smartphone camera, we detect inactivity and chest compressions and measure chest compression rate with real-time feedback to both the caller who performs chest compressions and over the web to the dispatcher who coaches the caller on chest compressions. The application estimates compression rate with 0.5 s update interval, time to first stable compression rate (TFSCR), active compression time (TC), hands-off time (TWC), average compression rate (ACR), and total number of compressions (NC). Four experiments were performed to test the accuracy of the calculated chest compression rate under different conditions, and a fifth experiment was done to test the accuracy of the CPR summary parameters TFSCR, TC, TWC, ACR, and NC. Average compression rate detection error was 2.7 compressions per minute (±5.0 cpm), the calculated chest compression rate was within ±10 cpm in 98% (±5.5) of the time, and the average error of the summary CPR parameters was 4.5% (±3.6). The results show that real-time chest compression quality measurement by smartphone camera in simulated cardiac arrest is feasible under the conditions tested.nb_NO
dc.description.abstractReal-Time Chest Compression Quality Measurements by Smartphone Cameranb_NO
dc.language.isoengnb_NO
dc.publisherHindawinb_NO
dc.relation.urihttps://www.hindawi.com/journals/jhe/2018/6241856/
dc.subjecthjerteinfarktnb_NO
dc.subjectout-of-hospital cardiac arrestnb_NO
dc.subjectchest compressionsnb_NO
dc.subjectsmartphone applicationnb_NO
dc.subjecthjertestans utenfor sykehusnb_NO
dc.titleReal-Time Chest Compression Quality Measurements by Smartphone Cameranb_NO
dc.title.alternativeReal-Time Chest Compression Quality Measurements by Smartphone Cameranb_NO
dc.typeJournal articlenb_NO
dc.typePeer reviewednb_NO
dc.description.versionpublishedVersionnb_NO
dc.rights.holderCopyright ©2018 Øyvind Meinich-Bache et al.nb_NO
dc.subject.nsiVDP::Medisinske Fag: 700nb_NO
dc.source.pagenumber12nb_NO
dc.source.volume2018nb_NO
dc.source.journalJournal of Healthcare Engineeringnb_NO
dc.identifier.doihttps://doi.org/10.1155/2018/6241856
dc.identifier.cristin1627965
cristin.unitcode217,8,4,0
cristin.unitnameInstitutt for data- og elektroteknologi
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Tilhørende fil(er)

Thumbnail

Denne innførselen finnes i følgende samling(er)

Vis enkel innførsel