Show simple item record

dc.contributor.authorCandefjord, Stefan
dc.contributor.authorNguyen, Linh
dc.contributor.authorBuendia, Ruben
dc.contributor.authorOropeza-Moe, Marianne
dc.contributor.authorAndersen, Nina Gjerde
dc.contributor.authorFhager, Andreas
dc.contributor.authorPersson, Mikael
dc.contributor.authorElam, Mikael
dc.contributor.authorOveland, Nils Petter
dc.date.accessioned2022-04-01T08:13:53Z
dc.date.available2022-04-01T08:13:53Z
dc.date.created2022-01-04T18:21:00Z
dc.date.issued2021-12
dc.identifier.citationCandefjord, S., Nguyen, L., Buendia, R., Oropeza-Moe, M., Andersen, N. G., Fhager, A., Persson, M., Elam, M., Oveland, N.P. (2021) A wearable microwave instrument can detect and monitor traumatic abdominal injuries in a porcine model. Scientific Reports, 11 (1), 23220 (2021) .en_US
dc.identifier.issn2045-2322
dc.identifier.urihttps://hdl.handle.net/11250/2989077
dc.description.abstractAbdominal injury is a frequent cause of death for trauma patients, and early recognition is essential to limit fatalities. There is a need for a wearable sensor system for prehospital settings that can detect and monitor bleeding in the abdomen (hemoperitoneum). This study evaluates the potential for microwave technology to fill that gap. A simple prototype of a wearable microwave sensor was constructed using eight antennas. A realistic porcine model of hemoperitoneum was developed using anesthetized pigs. Ten animals were measured at healthy state and at two sizes of bleeding. Statistical tests and a machine learning method were used to evaluate blood detection sensitivity. All subjects presented similar changes due to accumulation of blood, which dampened the microwave signal (p<0.05). The machine learning analysis yielded an area under the receiver operating characteristic (ROC) curve (AUC) of 0.93, showing 100% sensitivity at 90% specificity. Large inter-individual variability of the healthy state signal complicated differentiation of bleedings from healthy state. A wearable microwave instrument has potential for accurate detection and monitoring of hemoperitoneum, with automated analysis making the instrument easy-to-use. Future hardware development is necessary to suppress measurement system variability and enable detection of smaller bleedings.en_US
dc.language.isoengen_US
dc.publisherSpringer Nature Switzerland AGen_US
dc.rightsNavngivelse 4.0 Internasjonal*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/deed.no*
dc.subjecttraumatologien_US
dc.subjectakuttmedisinen_US
dc.subjectmikrobølgeren_US
dc.titleA wearable microwave instrument can detect and monitor traumatic abdominal injuries in a porcine modelen_US
dc.typePeer revieweden_US
dc.typeJournal articleen_US
dc.description.versionpublishedVersionen_US
dc.rights.holder© The Author(s) 2021en_US
dc.subject.nsiVDP::Medisinske Fag: 700::Klinisk medisinske fag: 750::Traumatologi: 783en_US
dc.source.pagenumber10en_US
dc.source.volume11en_US
dc.source.journalScientific Reportsen_US
dc.source.issue1en_US
dc.identifier.doi10.1038/s41598-021-02008-5
dc.identifier.cristin1974706
dc.source.articlenumber23220 (2021)en_US
cristin.ispublishedtrue
cristin.fulltextoriginal
cristin.qualitycode1


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Navngivelse 4.0 Internasjonal
Except where otherwise noted, this item's license is described as Navngivelse 4.0 Internasjonal